Introduction:
PHOTOMETER FOR AUTOMATIC CONTROL is widely used the photometry (luminance) measurement and automatic control in tunnels, square, hall, outdoor, waterunder, industry locality etc. The shield of photometer head is made of macromolecule material, stainless steel and glass. It is full-sealed, and can work under atrocious conditions because of its fine performance as waterproofed, dustproofed, rotproofed etc.

Specifications:
Full-sealed Photometer Head
1) Power supply requirement:DC 20V~25V<40mA

2) Measuring function(luminance ) and range:
Luminance:0~6500cd/m 2 (Outdoor type)0~300cd/m 2 (Indoor type)On user request
3) Analog output (current or voltage output according to user's demands )
Current outputDC 4mA~20mA
Voltage outputDC 0V~5V or 1V~5V

4) Maximum external load:
Current output type250~800
Voltage output type: The input impedance of connected photometer is required>100k

5) Measuring accuracy3%

6) Fieldsaplomb 30°, level 40°or 20(on user’s requests)

7) Length of signal line: 10m (Special 100m)

8) Full-sealed, waterproofed, dustproofed, rotproofed, and can work all full day

9) Working temperature- 25℃~50℃

10) Protection level: IP65 or IP68 (optional)

11) Safety level: Self initial safe type

12) AC adapter is optional on request
Input: AC 100V~240V, 50Hz/60Hz
Output: DC 24V±10%,100mA

PHOTO-2000 PHOTOMETER
The full-sealed photometer head can be configured with photometer for the direct luminance display.


1) PHOTO-2000PQ PHOTOMETER
1) Power supply requirement: AC 90V~265V /50Hz~60Hz
2) Analog input (optional): current: DC 4mA~20mA / Voltage: DC 0V~5V or 1V~5V
3) voltage output, supply for photometer head: DC 24V±10%, <50mA
4) 4 digit LED display: -1999~9999
5) Accuracy: 0.5%F.S±1digit
6) RS-232 interface (optional)
7) user' s zero and calibration function
8) It can work with the full-sealed photometer head
9) Dimension:151mm×76mm
2) PHOTO-2000Z PHOTOMETER
1) Power supply requirement: 220V±10%/50Hz~60Hz
2) Analog input (optional)
current: DC 4mA~20mA
Voltage: DC 0V~5V or 1V~5V
3) Voltage output, supply for photometer head: DC 24V±10%,<10mA
4) 4 digit LED display: 0~±9999
5) Accuracy: 0.5%
6) RS-232 interface (optional)
7) User's zero and calibration function
8) when DC 4mA~20mA current is linely output, the output capability is up to 800
9) it can be equipped with the full-sealed photometer head